简单介绍

FFAP/6201填充柱测定车间空气中的甲酸,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂,甲缩醛,乙缩醛,乙醇,乙酸乙酯,芝麻香白酒,3-甲硫基丙醇

FFAP/6201 充柱测定车间空气中的甲酸的详细介绍

FFAP/6201填充柱测定车间空气中的甲酸
FFAP/6201填充柱测定车间空气中的甲酸详细信息:

固定液:聚乙二醇硝基苯改性

担体:6201
型号:FFAP
规格:2m*3mm
配比:FFAP:6201=10:100
材质:不锈钢
应用:车间空气中的甲酸测定

滕州市浩瀚色谱仪器技术服务有限公司,用顶空气相色谱法同时测定工作场所空气中,甲酸、乙酸、丙酸和丙烯酸4种羧酸类化合物的适宜条件。流量为300 m L/min采集空气试样4.5 L,经硫酸溶液解吸后,在顶空平衡时间为60 min,平衡温度为50℃条件下用气相色谱FID检测器,以FFAP填充柱柱分离测定。甲酸、乙酸、丙酸和丙烯酸的加标回收率分别为95.3%、96.8%、105%和94.6%;方法zui低检出浓度分别为0.4 mg/m3、7.7 mg/m3、3.4 mg/m3和6.6 mg/m3;相对标准偏差(RSD)为5.84%~8.98%。结果表明,该方法有较高的灵敏度和理想的准确度,并能达到规定的检出限,适用于制革车间空气中羧酸类化合物的测定。

FFAP/6201填充柱测定车间空气中的甲酸测试谱图:


FFAP/6201 packed column to determine formic acid in the air of workshop
FFAP/6201 packed column to determine formic acid in the air of the workshop. Detailed information:

Fixing fluid: polyethylene glycol nitrobenzene modified

Carrier: 6201
Model: FFAP
Specification: 2m*3mm
Ratio: FFAP:6201=10:100
Material: Stainless steel
Application: Determination of formic acid in workplace air

Tengzhou Haohan Chromatography Instrument Technology Service Co., Ltd. uses headspace gas chromatography to simultaneously determine suitable conditions for four carboxylic acid compounds in the air of workplaces: formic acid, acetic acid, propionic acid and acrylic acid. A flow rate of 300 m L/min was used to collect 4.5 L of air sample. After being desorbed by sulfuric acid solution, the headspace equilibrium time was 60 min, and the equilibrium temperature was 50℃. The gas chromatography FID detector was used for separation and determination with FFAP packed column. . The spiked recoveries of formic acid, acetic acid, propionic acid and acrylic acid were 95.3%, 96.8%, 105%, and 94.6%, respectively; the minimum detection concentrations of the method were 0.4 mg/m3, 7.7 mg/m3, 3.4 mg/m3 and 6.6 mg/m3; relative standard deviation (RSD) is 5.84%~8.98%. The results show that the method has high sensitivity and ideal accuracy, and can reach the specified detection limit. It is suitable for the determination of carboxylic acid compounds in the air of tannery workshops.

FFAP/6201 packed column to determine the test spectrum of formic acid in the air of workshop:


相关产品

3mm*3m,, 401脱氧柱应用工业氢/安捷伦8860
401脱氧柱应用工业氢/安捷伦8860,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
HH-SO2,, 脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890
脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
60%苯基-全氟烷基聚硅氧烷, 全氟己酮灭火剂测定毛细管柱
全氟己酮灭火剂测定毛细管柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水
2m*3mm,, 5%Carbowax20M Carbopack B填充柱岛津
5%Carbowax20M Carbopack B填充柱岛津,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
HH-NH3-LJ790 气相色谱法测定氨裂解制氢催化剂活性
气相色谱法测定氨裂解制氢催化剂活性,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
3MM*2M,,, TDX-01填充柱应用之岛津GC-2030
TDX-01填充柱应用之岛津GC-2030,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 11*1等于多少?答案:11
 
主营产品:通用气相色谱仪、便携式气相色谱仪、高效液相色谱仪、在线气相色谱仪、实验室纯水机、顶空进样器、自动进样器等... 网站首页联系我们
仪器交易网
10
推荐收藏该企业网站