Thermo Scientific 赛默飞HH-WAX毛细管色谱柱
产品名称:Thermo Scientific 赛默飞HH-WAX毛细管色谱柱
产品型号:Thermo Scientific
产品厂商:浩瀚色谱(山东)应用技术开发有限公司
简单介绍
赛默飞HH-WAX毛细管色谱柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,变压器油溶解气,裂解进样器,三甲胺,变压器油溶解气,乙酸乙酯,芝麻香白酒,3-甲硫基丙醇,氨水,氨气
Thermo Scientific 赛默飞HH-WAX毛细管色谱柱的详细介绍
赛默飞HH-WAX毛细管色谱柱
赛默飞HH-WAX毛细管色谱柱 详细信息:
名称:毛细管柱
固定液:聚乙二醇
规格:60m*0.25mm*0.25um
型号:赛默飞HH-WAX
应用:GB 5009.266-2016 食品安家标准 食品中甲醇的测定
滕州市浩瀚色谱仪器技术服务有限公司,取样品0.100 0g用5.0mL水超声溶解,并引入顶空进样仪中,在80℃下加热30min达到平衡。对溶液中甲醇经顶空提取后,以HH-WAX毛细管色谱柱为固定相进行气相色谱分离。质谱分析中采用选择离子监测模式,外标法定量。甲醇的质量浓度在0.50~100mg·L~(-1)内与其峰面积呈线性关系,检出限(3S/N)为0.002 5%。按标准加入法进行回收试验,测得回收率在90.0%~之间,测定值的相对标准偏差(n=6)均小于2.2%。
赛默飞HH-WAX毛细管色谱柱 测试谱图:


Thermo Scientific HH-WAX Capillary Column
Thermo Scientific HH-WAX Capillary Column Details:
Name: Capillary column
Fixative: polyethylene glycol
Specifications: 60m*0.25mm*0.25um
Model: Thermo Fisher HH-WAX
Application: GB 5009.266-2016 Natio nal Food Safety Standard Determination of methanol in food
Tengzhou Haohan Chromatography Instrument Technology Service Co., Ltd., took a sample of 0.100 0g and dissolved it with 5.0 mL of water, and introduced it into the headspace sampler. It was heated at 80°C for 30 minutes to reach equilibrium. After the methanol in the solution was extracted by headspace, HH-WAX capillary chromatography column was used as the statio nary phase for gas chromatography separation. In the mass spectrometry analysis, the selected ion mo nitoring mode is adopted, and the external standard method is used for quantification. The mass co ncentration of methanol is linearly related to its peak area within 0.50~100mg·L~(-1), and the detection limit (3S/N) is 0.002 5%. The recovery test was carried out according to the standard addition method, and the measured recovery rate was between 90.0% and , and the relative standard deviation (n=6) of the measured values was less than 2.2%.
Thermo Scientific HH-WAX capillary column test spectrum:
赛默飞HH-WAX毛细管色谱柱 详细信息:
名称:毛细管柱
固定液:聚乙二醇
规格:60m*0.25mm*0.25um
型号:赛默飞HH-WAX
应用:GB 5009.266-2016 食品安家标准 食品中甲醇的测定
滕州市浩瀚色谱仪器技术服务有限公司,取样品0.100 0g用5.0mL水超声溶解,并引入顶空进样仪中,在80℃下加热30min达到平衡。对溶液中甲醇经顶空提取后,以HH-WAX毛细管色谱柱为固定相进行气相色谱分离。质谱分析中采用选择离子监测模式,外标法定量。甲醇的质量浓度在0.50~100mg·L~(-1)内与其峰面积呈线性关系,检出限(3S/N)为0.002 5%。按标准加入法进行回收试验,测得回收率在90.0%~之间,测定值的相对标准偏差(n=6)均小于2.2%。
赛默飞HH-WAX毛细管色谱柱 测试谱图:


Thermo Scientific HH-WAX Capillary Column
Thermo Scientific HH-WAX Capillary Column Details:
Name: Capillary column
Fixative: polyethylene glycol
Specifications: 60m*0.25mm*0.25um
Model: Thermo Fisher HH-WAX
Application: GB 5009.266-2016 Natio
Tengzhou Haohan Chromatography Instrument Technology Service Co., Ltd., took a sample of 0.100 0g and dissolved it with 5.0 mL of water, and introduced it into the headspace sampler. It was heated at 80°C for 30 minutes to reach equilibrium. After the methanol in the solution was extracted by headspace, HH-WAX capillary chromatography column was used as the statio
Thermo Scientific HH-WAX capillary column test spectrum: