HH-Tamine30毛细管柱 气相色谱法测定环境空气中三甲胺
产品名称:HH-Tamine30毛细管柱 气相色谱法测定环境空气中三甲胺
产品型号:HH-Tamine30毛细管柱
产品厂商:浩瀚色谱(山东)应用技术开发有限公司
简单介绍
气相色谱法测定环境空气中三甲胺,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,增塑剂,二叔丁基过氧化物
HH-Tamine30毛细管柱 气相色谱法测定环境空气中三甲胺的详细介绍
气相色谱法测定环境空气中三甲胺
气相色谱法测定环境空气中三甲胺 详细信息:
浩瀚色谱(山东)应用技术开发有限公司采用HH-Tamine30胺专用毛细管柱分离三甲胺,FID检测。该方法有较高灵敏度和良好的线性关系。结果表明:在柱温40℃,进样口温度180℃,检测器温度180℃,氮流量30mL/min时,平均回收率为100 3%,相对标准差为3%。
气相色谱法测定环境空气中三甲胺 测试谱图:





Determination of Trimethylamine in Ambient Air by Gas Chromatography
Determination of Trimethylamine in Ambient Air by Gas Chromatography
Name: Quartz Capillary Column
Statio nary phase: dimethyl polysiloxane (requires alkaline deactivation treatment)
Specification: 30m*0.32mm*5um
Model: HH-Tamine30
Application: Determination of Ambient Air and Waste Gas Trimethylamine Solution Absorption-Headspace Gas Chromatography
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. uses HH-Tamine30 amine special capillary column to separate trimethylamine and FID detection. This method has high sensitivity and good linearity. The results show that when the column temperature is 40℃, the inlet temperature is 180℃, the detector temperature is 180℃, and the nitrogen flow rate is 30mL/min, the average recovery rate is 100 3%, and the relative standard deviation is 3%.
Determination of Trimethylamine in Ambient Air by Gas Chromatography Test Spectra:
气相色谱法测定环境空气中三甲胺 详细信息:
名称:石英毛细管柱
固定相:二甲基聚硅氧烷(需碱性脱活处理)
规格:30m*0.32mm*5um
型号:HH-Tamine30
应用: 环境空气和废气 三甲胺的测定 溶液吸收-顶空 气相色谱法
浩瀚色谱(山东)应用技术开发有限公司采用HH-Tamine30胺专用毛细管柱分离三甲胺,FID检测。该方法有较高灵敏度和良好的线性关系。结果表明:在柱温40℃,进样口温度180℃,检测器温度180℃,氮流量30mL/min时,平均回收率为100 3%,相对标准差为3%。
气相色谱法测定环境空气中三甲胺 测试谱图:





Determination of Trimethylamine in Ambient Air by Gas Chromatography
Determination of Trimethylamine in Ambient Air by Gas Chromatography
Name: Quartz Capillary Column
Statio
Specification: 30m*0.32mm*5um
Model: HH-Tamine30
Application: Determination of Ambient Air and Waste Gas Trimethylamine Solution Absorption-Headspace Gas Chromatography
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. uses HH-Tamine30 amine special capillary column to separate trimethylamine and FID detection. This method has high sensitivity and good linearity. The results show that when the column temperature is 40℃, the inlet temperature is 180℃, the detector temperature is 180℃, and the nitrogen flow rate is 30mL/min, the average recovery rate is 100 3%, and the relative standard deviation is 3%.
Determination of Trimethylamine in Ambient Air by Gas Chromatography Test Spectra:
相关产品
在线留言 |