欢迎光临浩瀚色谱(山东)应用技术开发有限公司!
服务热线:0632-5667636
HH-Modified polymer 甲醛、乙醛分析测定专用填充柱

HH-Modified polymer 甲醛、乙醛分析测定专用填充柱

如果你感兴趣的话,可以电话:0632-5667636

产品名称:HH-Modified polymer 甲醛、乙醛分析测定专用填充柱

产品型号:HH-Modified polymer

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

甲醛、乙醛分析测定专用填充柱,芝麻香白酒,3-甲硫基丙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,增塑剂,塑化剂,氨水,氨气,消毒剂,增塑剂,乙酸乙酯,氨水

HH-Modified polymer 甲醛、乙醛分析测定专用填充柱的详细介绍

甲醛、乙醛分析测定专用填充柱
甲醛、乙醛分析测定专用填充柱 详细信息:

名称:填充柱
固定相:专用
规格:2m*3mm
材质:聚四氟乙烯管
型号:HH-Modified polymer

甲醛量、乙醛量的衍生化条件,甲醛、乙醛与2,4-二硝基苯肼溶液在60℃水浴中加热60 min衍生化反应, 此法操作复杂,费时费力,不环保。

浩瀚色谱(山东)应用技术开发有限公司,研发专用填充柱HH-Modified polymer直接测定甲醛,乙醛,结果甲醛、乙醛分离度为3.6,甲醛的线性范围为0.028~9.23μg.mL 1(r=0.999 4),平均回收率(n=9)为102.6%(RSD=0.9%),定量限为3.7×10 6μg、检测限为1.8×10 6μg;乙醛的线性范围为0.063~20.90μg.mL 1(r=0.999 5),平均回收率(n=9)为102.0%(RSD=1.2%),定量限为1.1×10 4μg、检测限为5.5×10 5μg。结论本法准确、灵敏,为甲醛、乙醛的安全监测提供检测依据。


甲醛、乙醛分析测定专用填充柱 测试谱图:




Packed column for analysis and determination of formaldehyde and acetaldehyde
Packed column for analysis and determination of formaldehyde and acetaldehyde Details:

Name: Packed column
Stationary phase: dedicated
Specification: 2m*3mm
Material: PTFE tube
Model: HH-Modified polymer

The derivatization conditions of the amount of formaldehyde and acetaldehyde, the derivatization reaction of formaldehyde, acetaldehyde and 2,4-dinitrophenylhydrazine solution heated in a 60℃ water bath for 60 min, this method is complicated to operate, time-consuming, laborious, and not environmentally friendly.

Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. has developed a special packed column HH-Modified polymer to directly determine formaldehyde and acetaldehyde. The result is that the resolution of formaldehyde and acetaldehyde is 3.6, and the linear range of formaldehyde is 0.028~9.23μg.mL 1(r =0.999 4), the average recovery rate (n=9) was 102.6% (RSD=0.9%), the limit of quantification was 3.7×10 6 μg, and the limit of detection was 1.8×10 6 μg; the linear range of acetaldehyde was 0.063-20.90 μg. mL 1 (r=0.999 5), the average recovery rate (n=9) was 102.0% (RSD=1.2%), the limit of quantification was 1.1×10 4 μg, and the limit of detection was 5.5×10 5 μg. Conclusion This method is accurate and sensitive, and provides a basis for the safety monitoring of formaldehyde and acetaldehyde.


Special packed column for the analysis and determination of formaldehyde and acetaldehyde Test spectrum:

相关产品

3mm*3m,, 401脱氧柱应用工业氢/安捷伦8860
401脱氧柱应用工业氢/安捷伦8860,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
HH-SO2,, 脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890
脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
60%苯基-全氟烷基聚硅氧烷, 全氟己酮灭火剂测定毛细管柱
全氟己酮灭火剂测定毛细管柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水
2m*3mm,, 5%Carbowax20M Carbopack B填充柱岛津
5%Carbowax20M Carbopack B填充柱岛津,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
HH-NH3-LJ790 气相色谱法测定氨裂解制氢催化剂活性
气相色谱法测定氨裂解制氢催化剂活性,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
3MM*2M,,, TDX-01填充柱应用之岛津GC-2030
TDX-01填充柱应用之岛津GC-2030,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 1+0等于多少?答案:1
 
主营产品:通用气相色谱仪、便携式气相色谱仪、高效液相色谱仪、在线气相色谱仪、实验室纯水机、顶空进样器、自动进样器等... 网站首页联系我们
仪器交易网
9
推荐收藏该企业网站