欢迎光临浩瀚色谱(山东)应用技术开发有限公司!
服务热线:0632-5667636
PEG-20M毛细管柱 气相色谱法测定医疗防护用品中环氧乙烷残留

PEG-20M毛细管柱 气相色谱法测定医疗防护用品中环氧乙烷残留

如果你感兴趣的话,可以电话:0632-5667636

产品名称:PEG-20M毛细管柱 气相色谱法测定医疗防护用品中环氧乙烷残留

产品型号:PEG-20M毛细管柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

气相色谱法测定医疗防护用品中环氧乙烷残留,液化石油气,二甲醚·。甲缩醛,口罩,医疗器械,环氧乙烷,三甲胺,二甲醚,乙缩醛,乙醇,变压器油,多氯联苯,植物油,增塑剂,塑化剂

PEG-20M毛细管柱 气相色谱法测定医疗防护用品中环氧乙烷残留的详细介绍

气相色谱法测定医疗防护用品中环氧乙烷残留
气相色谱法测定医疗防护用品中环氧乙烷残留 详细信息:

名称:毛细管柱
规格:30m*0.32mm*0.25um
型号:PEG-20M
应用: 气相色谱法测定医疗防护用品中环氧乙烷残留

口罩是抗击新型冠状病毒的贴身小卫士,一次性医用口罩生产过程中使用环氧乙烷灭菌消毒。环氧乙烷为什么具有灭菌的作用呢?让我们一起了解环氧乙烷的组成、类别、性质及灭菌原理,揭开一次性医用口罩灭菌的奥秘吧! 

浩瀚色谱(山东)应用技术开发有限公司建立气相色谱法检测口罩、防护服等医疗防护用品中环氧乙烷的残留量,为生产厂家改进灭菌工艺提供数据支持。气相色谱法采用顶空进样、FID检测器,环氧乙烷的质量浓度在0.5~8 μg/mL范围内与色谱峰面积线性关系良好,检出限为0.10 μg/g,定量限为0.35 μg/g。环氧乙烷测定结果的相对标准偏差为1.73%(n=6),平均加标回收率为94.3%~99.3%。该方法操作简便,精密度、准确度较高,适用于医疗防护用品中环氧乙烷的测定。 



Determination of ethylene oxide residues in medical protective equipment by gas chromatography
Determination of ethylene oxide residues in medical protective equipment by gas chromatography Details:

Name: capillary column
Specifications: 30m*0.32mm*0.25um
Model: PEG-20M
Application: Determination of ethylene oxide residues in medical protective equipment by gas chromatography

Masks are personal guards against the new coronavirus. Ethylene oxide is used for sterilization and disinfection in the production process of disposable medical masks. Why does ethylene oxide have the effect of sterilization? Let us understand the composition, types, properties and sterilization principles of ethylene oxide together, and uncover the mystery of sterilization of disposable medical masks!

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has established a gas chromatography method to detect the residual amount of ethylene oxide in medical protective equipment such as masks and protective clothing, and provide data support for manufacturers to improve the sterilization process. Gas chromatography adopts headspace injection and FID detector. The mass concentration of ethylene oxide has a good linear relationship with the chromatographic peak area in the range of 0.5-8 μg/mL. The detection limit is 0.10 μg/g, and the quantification limit is 0.35. μg/g. The relative standard deviation of the determination results of ethylene oxide was 1.73% (n=6), and the average recovery was 94.3%-99.3%. The method is easy to operate, has high precision and accuracy, and is suitable for the determination of ethylene oxide in medical protective equipment. 

相关产品

3mm*3m,, 401脱氧柱应用工业氢/安捷伦8860
401脱氧柱应用工业氢/安捷伦8860,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
HH-SO2,, 脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890
脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
60%苯基-全氟烷基聚硅氧烷, 全氟己酮灭火剂测定毛细管柱
全氟己酮灭火剂测定毛细管柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水
2m*3mm,, 5%Carbowax20M Carbopack B填充柱岛津
5%Carbowax20M Carbopack B填充柱岛津,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
HH-NH3-LJ790 气相色谱法测定氨裂解制氢催化剂活性
气相色谱法测定氨裂解制氢催化剂活性,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
3MM*2M,,, TDX-01填充柱应用之岛津GC-2030
TDX-01填充柱应用之岛津GC-2030,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 1+0等于多少?答案:1
 
主营产品:通用气相色谱仪、便携式气相色谱仪、高效液相色谱仪、在线气相色谱仪、实验室纯水机、顶空进样器、自动进样器等... 网站首页联系我们
仪器交易网
10
推荐收藏该企业网站