GDX-407填充柱 测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015

GDX-407填充柱 测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015

如果你感兴趣的话,可以电话:0632-5667636

产品名称:GDX-407填充柱 测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015

产品型号:GDX-407填充柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂

GDX-407填充柱 测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015的详细介绍

测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015
测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015 详细信息:

名称:填充柱

固定相:有机担体

粒度:80-100目,60-80目

规格:2m*4mm,2m*3mm ,2m*1*8

型号:407有机担体 ,GDX-407
应用:  GB/T 16886.7-2015医疗器械生物学评价 第7部分:环氧乙烷灭菌残留量



浩瀚色谱(山东)应用技术开发有限公司建立气相色谱法检测口罩、防护服等医疗防护用品中环氧乙烷的残留量,为生产厂家改进灭菌工艺提供数据支持。气相色谱法采用顶空进样、FID检测器,环氧乙烷的质量浓度在0.5~8 μg/mL范围内与色谱峰面积线性关系良好,检出限为0.10 μg/g,定量限为0.35 μg/g。环氧乙烷测定结果的相对标准偏差为1.73%(n=6),平均加标回收率为94.3%~99.3%。该方法操作简便,精密度、准确度较高,适用于医疗防护用品中环氧乙烷的测定。 

测定医疗防护用品中环氧乙烷残留量GB/T 16886.7-2015   测试谱图:




Determination of ethylene oxide residues in medical protective equipment GB/T 16886.7-2015
Determination of ethylene oxide residues in medical protective equipment GB/T 16886.7-2015 Details:

Name: Packed Column

Stationary Phase: Organic Support

Particle size: 80-100 mesh, 60-80 mesh

Specifications: 2m*4mm, 2m*3mm, 2m*1*8

Model: 407 organic carrier, GDX-407
Application: GB/T 16886.7-2015 Biological evaluation of Medical Devices Part 7: Residues of Ethylene Oxide Sterilization



Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. has established a gas chromatography method to detect the residual amount of ethylene oxide in medical protective equipment such as masks and protective clothing, and provide data support for manufacturers to improve the sterilization process. Gas chromatography adopts headspace injection and FID detector. The mass concentration of ethylene oxide has a good linear relationship with the chromatographic peak area in the range of 0.5-8 μg/mL. The detection limit is 0.10 μg/g, and the quantification limit is 0.35. μg/g. The relative standard deviation of the determination results of ethylene oxide was 1.73% (n=6), and the average recovery was 94.3%-99.3%. The method is easy to operate, has high precision and accuracy, and is suitable for the determination of ethylene oxide in medical protective equipment.

Determination of ethylene oxide residues in medical protective equipment GB/T 16886.7-2015 Test spectrum:

相关产品

3mm*3m,, 401脱氧柱应用工业氢/安捷伦8860
401脱氧柱应用工业氢/安捷伦8860,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
HH-SO2,, 脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890
脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
60%苯基-全氟烷基聚硅氧烷, 全氟己酮灭火剂测定毛细管柱
全氟己酮灭火剂测定毛细管柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水
2m*3mm,, 5%Carbowax20M Carbopack B填充柱岛津
5%Carbowax20M Carbopack B填充柱岛津,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
HH-NH3-LJ790 气相色谱法测定氨裂解制氢催化剂活性
气相色谱法测定氨裂解制氢催化剂活性,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
3MM*2M,,, TDX-01填充柱应用之岛津GC-2030
TDX-01填充柱应用之岛津GC-2030,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水