欢迎光临浩瀚色谱(山东)应用技术开发有限公司!
服务热线:0632-5667636
PEG-20M毛细管柱 尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析

PEG-20M毛细管柱 尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析

如果你感兴趣的话,可以电话:0632-5667636

产品名称:PEG-20M毛细管柱 尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析

产品型号:PEG-20M毛细管柱

产品厂商:浩瀚色谱(山东)应用技术开发有限公司

简单介绍

尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,增塑剂,塑化剂,消毒剂,氨水,氨气,炼厂气,过氧化物,苯系物

PEG-20M毛细管柱 尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析的详细介绍

尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析
尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析 详细信息:

名称:毛细管柱
固定相:聚乙二醇
规格:30m*0.53mm*1.0um
型号:PEG-20M
应用:GBZ∕T 312-2018 尿中N-甲基乙酰胺测定 气相色谱法

浩瀚色谱(山东)应用技术开发有限公司建立直接进样-气相色谱法检测尿中N-甲基乙酰胺(NMAC),为研制职业接触二甲基乙酰胺生物限值提供配套检测方法.方法 用甲醇稀释经冷冻离心的尿样,分离蛋白沉淀后直接进样,经聚乙二醇毛细管色谱柱程序升温分离,氮磷检测器检测.结果 尿中NMAC的线性范围为1.0~250 mg/L,相关系数为1.0000;低检测浓度为0.2 mg/L;添加水平为10.58、52.90、211.60 mg/L时,NMAC回收率为96.0%~99.4%,平均回收率为97.8%;批内和批间相对标准偏差为1.5%~3.4%.结论 本方法简便快速,灵敏准确,适用于DMAC职业暴露人群尿样中NMAC的监测.


尿中N-甲基乙酰胺直接进样-氮磷检测气相色谱分析  测试谱图:



Direct Injection of N-methylacetamide in Urine - Gas Chromatographic Analysis of Nitrogen and Phosphorus Detection
Urine N-Methylacetamide Direct Injection-Gas Chromatographic Analysis for Nitrogen Phosphorus Detection Details:

Name: capillary column
Stationary Phase: Polyethylene Glycol
Specifications: 30m*0.53mm*1.0um
Model: PEG-20M
Application: GBZ∕T 312-2018 Determination of N-Methylacetamide in Urine Gas Chromatography

Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established a direct injection-gas chromatography method for the detection of N-methylacetamide (NMAC) in urine to provide a matching detection method for the development of the biological limit of occupational exposure to dimethylacetamide. The method used The refrigerated and centrifuged urine samples were diluted with methanol, and the proteins were precipitated and injected directly into the samples. They were separated by temperature-programmed polyethylene glycol capillary chromatographic columns and detected by nitrogen and phosphorus detectors. The linear range of NMAC in urine was 1.0-250 mg/L. The correlation coefficient was 1.0000; the lowest detection concentration was 0.2 mg/L; when the addition levels were 10.58, 52.90, and 211.60 mg/L, the NMAC recoveries were 96.0%-99.4%, and the average recovery was 97.8%; The standard deviation was 1.5%-3.4%. Conclusion The method is simple, rapid, sensitive and accurate, and suitable for the monitoring of NMAC in urine samples of people exposed to DMAC occupationally.


Direct injection of N-methylacetamide in urine - gas chromatographic analysis of nitrogen and phosphorus detection Test spectrum:

相关产品

3mm*3m,, 401脱氧柱应用工业氢/安捷伦8860
401脱氧柱应用工业氢/安捷伦8860,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
HH-SO2,, 脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890
脱二氧化硫管测定食品二氧化碳中总硫安捷伦7890,液化石油气,二甲醚,甲缩醛,乙缩醛,芝麻香白酒,3-甲硫基丙醇,杂醇油,氨气,氨水,消毒剂,乙缩醛,乙醇,增塑剂,塑化剂,口罩,医疗器械,环氧乙烷
60%苯基-全氟烷基聚硅氧烷, 全氟己酮灭火剂测定毛细管柱
全氟己酮灭火剂测定毛细管柱,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水
2m*3mm,, 5%Carbowax20M Carbopack B填充柱岛津
5%Carbowax20M Carbopack B填充柱岛津,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
HH-NH3-LJ790 气相色谱法测定氨裂解制氢催化剂活性
气相色谱法测定氨裂解制氢催化剂活性,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨
3MM*2M,,, TDX-01填充柱应用之岛津GC-2030
TDX-01填充柱应用之岛津GC-2030,液化石油气,二甲醚,甲缩醛,乙缩醛,乙醇,室内空气,焦炉煤气,炼厂气,天然气,变压器油,多氯联苯,植物油,6号溶剂残留,裂解进样器,氨水

在线留言

主题 *
内容 *
公司名
联系人 *
联系电话 *
电子邮箱
QQ
阿里旺旺
验证问题 * 2*0等于多少?答案:0
 
主营产品:通用气相色谱仪、便携式气相色谱仪、高效液相色谱仪、在线气相色谱仪、实验室纯水机、顶空进样器、自动进样器等... 网站首页联系我们
仪器交易网
10