PQ甲烷柱,总烃柱,预柱--- 固定污染源非甲烷总烃在线监测柱系统
产品名称:PQ甲烷柱,总烃柱,预柱--- 固定污染源非甲烷总烃在线监测柱系统
产品型号:PQ甲烷柱,总烃柱,预柱---
产品厂商:浩瀚色谱(山东)应用技术开发有限公司
简单介绍
固定污染源非甲烷总烃在线监测柱系统,液化石油气,顶空进样器,粗苯,三苯,二甲苯,芝麻香白酒,3-甲硫基丙醇,环氧乙烷,甲缩醛,甲醛,三甲胺
PQ甲烷柱,总烃柱,预柱--- 固定污染源非甲烷总烃在线监测柱系统的详细介绍
固定污染源非甲烷总烃在线监测柱系统
固定污染源非甲烷总烃在线监测柱系统 详细信息:
固定污染源非甲烷总烃在线监测柱系统 谱图:







o nline mo nitoring column system of non-methane total hydrocarbon from fixed pollution source
Details of o nline mo nitoring column system for non-methane total hydrocarbon of fixed pollution source:
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. carried out comparative mo nitoring on the non-methane total hydrocarbon o nline mo nitoring system of a typical enterprise's fixed pollution source, and compared and analyzed the o nline mo nitoring results with the portable instrument mo nitoring and manual mo nitoring results. The results show that the linear error and range drift of the o nline mo nitoring system can meet the management requirements at this stage. Different sampling and analysis instruments are used in the actual sample comparison process, and the mo nitoring results differ greatly. The relative error of the portable analyzer results is small (3 72%), the relative error of manual mo nitoring results is relatively large (48 3%)。 It is suggested to strengthen the quality co ntrol management of manual mo nitoring of waste gas from pollution sources, strengthen the operation and maintenance management of o nline mo nitoring equipment, and promote the ratio nal and orderly development of CEMS of non-methane total hydrocarbons from pollution sources.
Name: Silanized glass microsphere total hydrocarbon column
Specification: 0.6m * 1/8
No.: 20230225002 - (10)
Quantity: 10
*High temperature: 300 ° C
Name: Porapak Q filled column
Specification: 0.8m * 1/8, 60-80 mesh
No.: 20230225003 - (10)
Quantity: 10
*High temperature: 250 ° C
Name: GDX-502 methane column
Specification: 1.5m * 1/8, 60-80 mesh
No.: 20230225004 - (10)
Quantity: 10
*High temperature: 250 ° C
Name: Quantitative tube
Specification: 500ul
No.: 20230225001
Quantity: 20
*High temperature: 300 ° C
Spectrogram of o nline mo nitoring column system for non-methane total hydrocarbon of fixed pollution source:
固定污染源非甲烷总烃在线监测柱系统 详细信息:
浩瀚色谱(山东)应用技术开发有限公司对某典型企业固定污染源非甲烷总烃在线监测系统开展比对监测,将在线监测结果和便携式仪器监测、手工监测结果作比对分析。结果表明,在线监测系统线性误差与量程漂移可以满足现阶段管理要求,实际样品比对过程中采用不同的采样分析仪器,监测结果差距较大,便携式分析仪结果相对误差较小(为3. 72%),手工监测结果相对误差较大(为48. 3%)。建议加强污染源废气手工监测的质控管理,强化在线监测设备的运维管理,推进污染源非甲烷总烃CEMS合理有序发展。
名称:硅烷化玻璃微球总烃柱
规格:0.6m*1/8
编号:20230225002-(10)
数量:10个
*高温度:300°C
名称:Porapak Q填充柱
规格:0.8m*1/8,60-80目
编号:20230225003-(10)
数量:10个
*高温度:250°C
名称:GDX-502甲烷柱
规格:1.5m*1/8,60-80目
编号:20230225004-(10)
数量:10个
*高温度:250°C
名称:定量管
规格:500ul
编号:20230225001
数量:20个
*高温度:300°C
固定污染源非甲烷总烃在线监测柱系统 谱图:







o
Details of o
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. carried out comparative mo
Name: Silanized glass microsphere total hydrocarbon column
Specification: 0.6m * 1/8
No.: 20230225002 - (10)
Quantity: 10
*High temperature: 300 ° C
Name: Porapak Q filled column
Specification: 0.8m * 1/8, 60-80 mesh
No.: 20230225003 - (10)
Quantity: 10
*High temperature: 250 ° C
Name: GDX-502 methane column
Specification: 1.5m * 1/8, 60-80 mesh
No.: 20230225004 - (10)
Quantity: 10
*High temperature: 250 ° C
Name: Quantitative tube
Specification: 500ul
No.: 20230225001
Quantity: 20
*High temperature: 300 ° C
Spectrogram of o
相关产品
在线留言 |